How to measure inductors? Several methods to detect the quality of inductors
May 12, 2021
Leave a message
Inductance coils are made of wires that are wound on an insulating tube one by one. The wires are insulated from each other. The insulating tube can be hollow, or it can contain iron cores or magnetic powder cores, referred to as inductors. It is an energy storage element in the circuit. It is represented by "L", and the units are Henry (H), millihenry (mH), and microhenry (μH). Let's take a look at several methods of inductor measurement and detection.
The size of the inductance depends on the diameter of the inductor, the number of turns and the material of the intermediate medium. The error between the actual inductance and the nominal value of the inductance is called the accuracy of the inductance. Choose the appropriate accuracy according to the actual needs to avoid unnecessary waste. Under normal circumstances, the inductance used for oscillation requires higher accuracy, while the inductance used for coupling or choke requires lower accuracy. For some occasions that require high inductance accuracy, generally you have to wind it yourself and test it with an instrument, which is achieved by adjusting the number of turns or the position of the magnetic core or iron core in the inductor.

Two types of instruments for inductance measurement: RLC measurement (resistance, inductance, and capacitance can be measured) and inductance measuring instrument.
Inductance measurement: no-load measurement (theoretical value) and measurement in the actual circuit (actual value). Because the actual circuit used in the inductor is too much, it is difficult to classify. Only the measurement under no-load conditions is explained. Inductance measurement steps (RLC measurement):
1. Familiar with the operating rules of the instrument (instructions for use) and precautions.
2. Turn on the power and prepare for 15-30 minutes.
3. Select the L file and select the measurement inductance.
4. Clamp the two clamps to each other and reset to zero.
5. Clamp the two clamps to the two ends of the inductor, read the value and record the inductance.
6. Repeat steps 4 and 5 to record the measured value. There must be 5-8 data.
7. Compare several measured values: if the difference is not large (0.2μH), take the average value and remember the theoretical value of the inductance; if the difference is too large (0.3μH), repeat steps 2-step 6 until you get the theoretical value of the inductance value.

Three methods to detect the quality of inductors
1. Visual inspection
Directly observe whether the lead of the inductor is disconnected, whether the magnetic core is loose, whether the insulating material is damaged or burnt, etc.
2. Multimeter testing
In the judgment of the quality of the inductor, a multimeter is often used to measure the on-off and resistance value of the inductor. Place the multimeter in the Ω block, and connect the red and black test leads to any lead end of the inductor. At this time, the pointer should swing to the right. According to the measured resistance value, the judgment can be divided into the following three situations.
(1) The resistance value of the inductor under test is too small. It means that the internal coil of the inductor has a short-circuit fault. Pay attention to the test operation, be sure to set the multimeter to zero first, and carefully observe whether the position where the pointer swings to the right actually reaches the zero position to avoid misjudgment. When it is suspected that there is a short-circuit fault inside the inductor, it is best to repeat the test several times with the R×1 Ω block, so that a correct judgment can be made.
(2) The measured inductor has a resistance value. The DC resistance value of the inductor is directly related to the diameter of the enameled wire used to wind the inductor coil and the number of turns. The smaller the wire diameter and the more turns, the greater the resistance value. Under normal circumstances, use a multimeter to measure R×1 Ω. As long as the resistance value can be measured, the measured inductor can be considered normal.
(3) The resistance value of the measured inductor is infinite. This phenomenon is relatively easy to distinguish, indicating that an open-circuit fault has occurred at the coil or terminal of the inductor and the coil contact.
3. Insulation detection
Insulation detection is mainly for inductors with iron cores or metal shields. Place the multimeter in the R*1K file and measure the resistance between the coil lead and the iron core or metal shield. Normally, it is infinite (the needle does not move), otherwise the inductor is poorly insulated.
Note: When measuring a coil with a small inductance, it is good as long as the two ends of the measuring coil are electrically blocked.
In modern society, with the rapid development of technology, inductors have been integrated into every corner of our lives. And there are many types of inductors, and their functions are not the same, so we must buy inductors of suitable quality and guaranteed.
For more information, please contact us at sales@xfullstar.com