The AL value is the inductance factor, and the unit is mH / 100Turns or nH / T2.
Whether it is a specified inductance factor or a specified depth of air gap, it is determined during the manufacturing process. The following table lists the tolerance ranges.
Air gap on both sides and air gap on one side
Opening the air gap on both sides means that the air gap is symmetrical, and one air gap is opened on each side.
Air gaps on one side are asymmetric air gaps; all air gaps are on the same side, and the other side is not.
Specify the inductance to open the air gap
In most applications, the error of opening the air gap according to the inductance is small, and the difference in magnetic permeability and core shape will be reduced, so the electrical measurement is more accurate.
When selecting E-type cores (including EC, EFD, ETD, and flat E-type) to open the air gap according to the inductance value, you need to pay attention to whether to use air cores with air gaps on both sides, because the two are combined to achieve the required AL value. Another possible way is to use a single-sided air-gap core. The air-gap one can be used with another non-air-gap core to achieve the desired inductance. Magnet's tank, RS, DS, RM, PQ, and EP cores are sold in "pairs", regardless of whether the cores are open on either side or on one side.
Measure and calculate the value of AL to 3 digits after the decimal point, with the central value as the main factor. For example: AL = 99 ± 3% means the lowest value is 96, the central value is 99, and the highest value is 102. US Magnetics uses a wire-wrapped skeleton when measuring AL values, usually 250 turns for a 100-turn or deeper core. Use low drive power (5 Gauss) and then control at low frequencies to avoid resonance effects. The actual measured inductance value may be significantly different from the theoretical value due to insufficient turns, unsatisfactory windings, leakage inductance effects, resonance effects, and increased drive levels.
Comparing the correlation between the results of the core test and the inductor transformer test is very important for the design engineer. The flat E-type, flat RM-type, and flat PQ-type cores are particularly susceptible to the effects of correlation and differ.