Panar Transformer and Common Transformer
Apr 29, 2019
Leave a message
The Difference between Panar Transformer and Common Transformer
The biggest difference between planar transformer and traditional transformer lies in iron core and winding. Planar transformer uses small size E-type, RM-type or ring-type ferrite core, usually made of high-frequency power ferrite material, which has lower core loss at high frequency; windings are made of multi-layer printed circuit board, and windings or copper sheets are overlapped on the planar high-frequency core to form the magnetic circuit of transformer. This design has low DC copper resistance, low leakage inductance and distributed capacitance, which can meet the design requirements of resonant circuit. Moreover, the RF interference can be suppressed due to the good magnetic shielding of the core.
Compared with traditional transformers, planar transformers have the following characteristics:
(1) High current density. The conductor of planar transformer is actually some planar conductors, so the current density is high.
(2) High efficiency. The efficiency can reach 98%-99%.
(3) Low leakage. About 0.2% of the primary inductance.
(4) Good heat conduction. The distance of heat channel is short and the temperature rise is low.
(5) Low EMI radiation. Good core shielding can reduce radiation to a very low level.
(6) Small size. Small magnetic cores can reduce the volume accordingly.
(7) The parameters have good repeatability. Because the winding structure is fixed and pre-processed, the parameters are stable.
(8) Wide frequency range. Frequencies range from 50 kHz to 2 MHz.
(9) Wide operating temperature range. The working temperature is - 40 ~130 C.
(10) Good insulation. The planar transformer is composed of conductive circuit and insulating sheet overlapping each other, so as to ensure 4 kV insulation isolation between windings, primary-secondary and secondary-secondary.
Characteristic:
(1) Current distribution
Typical secondary windings of flat transformer have several parallel coils. Each secondary winding is coupled with the same primary winding. Therefore, the number of amperes produced by the secondary winding current is equal to the number of amperes produced by the primary winding (the excitation current is neglected). This characteristic is particularly useful for parallel rectifier circuits. The distribution of winding current is equal, so there is no need for current sharing resistance or other components in parallel rectifier circuit.
(2) High current density
Flat-plate transformer has excellent temperature rise characteristic design. Because of these characteristics, it can achieve high current density in very small packages.
(3) High efficiency
By adjusting the leakage inductance, it can have a very fast switching time and a very low cross-loss, so that it can achieve high efficiency. The inter-turn conduction loss between the secondary winding and the primary winding of this transformer is very small.
(4) High power density
Because of its small size and excellent temperature dissipation characteristics, flat-plate transformer can be closely packaged with related semiconductor devices and inductors to achieve high power density. Its current density can reach 30A/module.
(5) Low cost
The whole transformer is composed of a small number of related cheap components, and it is easy to assemble, so the cost of the transformer is very low.
(6) Save the cost of components connected to it
Because of its small leakage inductance and low switching loss, the stress on the components connected with it is reduced. Therefore, the components connected with it can use low-cost components with low power quotas.
(7) Excellent heat dissipation characteristics
Flat-plate transformer is a small component with high surface area volume ratio and short thermal channel. It is conducive to heat dissipation. The inter-turn loss between primary and secondary windings is very small. The special geometric shape of the core can effectively reduce the core loss. So it can achieve high flux density. It can work between - 40 130 C.
(8) Low leakage inductance
Good coupling between windings and windings can keep the leakage inductance between windings to a minimum. The connection between the output end and the auxiliary parts is very short and tightly assembled, so the leakage inductance of the windings connected to each other is the smallest.
(9) Excellent high frequency characteristics
Previously, when transformers were operating at high frequencies, switching losses increased and transformers overheated. These problems can be solved by the appearance of plate transformer. Flat-plate transformer can be designed as high frequency transformer, providing an economical and good transformer module. It can work between 100 kHz and 500 kHz.
(10) Simple structure
Flat-plate transformer is composed of a small number of components and the fewest windings. This module is especially suitable for automatic assembly.
(11) Low profile
The magnetic cores used in planar transformers are very small and can be arranged on the surface of planar transformers. The shape of each core unit ranges from 8 mm to 25 mm.
(12) High insulation strength
Flat-plate transformer can be easily insulated according to the required number of insulation layers and thickness. It can be dielectric insulated according to customer's requirement for leakage distance. The withstand voltage between primary and secondary windings is more than 40 000 V.