How to test the electrical performance of network transformer?
Jun 01, 2023
Leave a message
Lan transformers, known as "data mercury", are electronic components found in consumer PCI cards and all network communication and transmission devices. They can also be called network isolation transformers.
Classification of lan transformers
●T1/E1 isolation transformer;
●ISDN/ADSL interface transformer;
VDSL high-pass/low-pass filter module, interface transformer;
●T3/E3, SDH, 64KBPS interface transformer;
●10/100BASE, 1000BASE-TX network filter;
●DC-DC converter;
● Design special transformer according to customer needs.
The role of lan transformers
Lan transformer in Ethernet main role: signal transmission, impedance matching and conversion, waveform repair, signal clutter suppression, high voltage isolation and other roles. It is mainly used in routers, optical cats, docking stations, switches and so on.
In the network card is mainly used in the server, hub, personal computer, etc., has the following functions:
(1) Signal transmission: the differential signal sent out by PHY is coupled by the differential mode coupled coil to enhance the signal, and coupled to the other end of the connecting network cable with different levels through the conversion of electromagnetic field;
(2) Separate the different levels between different network devices connected by the network line to prevent the transmission of different voltages through the network cable to damage the equipment;
(3) play a certain role in lightning protection.
Introduction to electrical parameters of network transformer
The main electrical parameters of the network transformer are as follows:
Ratio of turns
Turn Ratio, primary and secondary coil turns ratio.
Insertion loss dB
Insertion Loss=20Xlog(V1/V2), where V1 is the output level after transformer insertion and V2 is the output level when transformer is not inserted. This parameter is used to measure the effect of transformer insertion on the transmitted signal. The smaller the better. Generally refers to the network transformer to signal attenuation degree and signal frequency relationship curve.
Return loss dB
Return Loss is the curve measuring the relationship between the system impedance mismatch degree and signal frequency after the network transformer is inserted. Return Loss=20Xlog(Vr/Vi), where Vr is the amplitude of reflected signal and Vi is the amplitude of incident signal.
Crossover interferes with dB
Cross Talk, the ratio of the signal V1 in one of the two cell circuits to the signal V2 induced in the other cell circuit Cross Talk =20Xlog(V2/V1).
Common-mode rejection ratio dB
CMRR=20Xlog(Vout/Vin), the ratio of the common-mode interference signal amplitude Vin at the input end of the network transformer to the common-mode interference signal amplitude Vout at the output end.
For more information, please contact us at sales@xfullstar.com