In a certain frequency, it is possible that copper loss and iron loss are equal, beyond this frequency, iron loss is greater than copper loss.
Causes of iron loss not equal to copper loss. Although the choice of wire thickness is affected by skin effect, it is mainly determined by the transmission power of high-frequency power transformer and has no direct relationship with the operating frequency. And, choose very fine enameled wire to be winding, can increase copper loss instead, defer the decline trend of copper loss. Perhaps in the design of the selected operating frequency, there may be copper loss is equal to iron loss. The operating frequency of the high-frequency power transformer of medium and small power is about 100kHz, and the iron loss is already greater than the copper loss, which has become the main part of the loss of high-frequency power transformer.
Because iron loss is the main part of high frequency power transformer loss, the selection of magnetic core material based on iron loss is a main content of high frequency power transformer design. Iron loss is also a main parameter to evaluate soft core materials. The iron loss is related to the working flux density and working frequency of the magnetic core. PB/f (where the unit of working flux density B is T (tesla) and the unit of working frequency f is Hz (Hertz)) must also be indicated when it is represented by a symbol.
For example, P0. 5/400 indicates that the working flux density is 0. 5T, loss at operating frequency of 400Hz. For example, P0. 1/100k indicates that the working flux density is 0. Loss at working frequency of 100kHz at 1T. Iron loss is related to the working temperature, the soft magnetic core material, metal loss must specify its working temperature, soft magnetic ferrite materials, in particular, is more sensitive to temperature changes, are listed in the product manual iron losses of 25 ℃ to 100 ℃. The saturation flux density of soft magnetic materials does not completely represent the upper limit of working flux density used, and it is often the iron loss that limits the upper limit of working flux density. Therefore, in the new classification standard of soft magnetic ferrite material for power transformer, the product B f of the allowable working flux density and working frequency is taken as the performance factor of the material, and the allowable loss value under the performance factor is explained. According to the new classification standard, soft ferrite materials are divided into five categories according to their performance factors, namely PW1, PW2, PW3, PW4 and PW5. The higher the performance factor is, the higher the working frequency is and the higher the limit frequency is. For example, PW3 soft magnetic ferrite material has a working frequency of 100kHz, a limit frequency of 300kHz, and a performance factor B f of 10000mT kHz, i.e. 1 t) and 100 KHZ, under 100 ℃ when the loss of a level 300 kw/m or less (300 mw/cm3), grade b or less 150 kw/m3 / cm3 (150 mw).
When the winding loss (copper loss) of the high-frequency power transformer is close to the iron loss at a certain operating frequency, for example, the copper loss cannot be ignored in the range of copper loss/iron loss = 100% ~ 25%, and measures should be taken to reduce the copper loss. As the power undertaken by the original winding and the auxiliary winding is similar, the copper loss of the original winding is often taken as the copper loss of the auxiliary winding in the design, so as to simplify the design calculation process. The high-frequency power transformer cannot only be designed according to the temperature rise. Because the thermal resistance is not easy to be accurately determined, the design calculation is rather troublesome. Therefore, in order to simplify the calculation, it is sometimes necessary to recommend some principles and data in advance according to experience. Similarly, in order to simplify the calculation, it is necessary to recommend different winding current densities for high-frequency power transformers with different working frequencies and powers, but not limited to a certain current density value, for example, 2A/mm2-3a/mm2. It should be noted that the design requirements for high-frequency power transformers are not limited to one method, but should be explored in a variety of ways.
For more information,please contact us at sales@xfullstar.com