Technical Parameters

 

Split-Core Current Sensor - IEC 61869 Class 0.5, Non-Invasive Retrofit CT for Energy Monitoring & SCADA

12.jpg

What this sensor is - and what it is not

A split-core current sensor (also called split-core CT) opens around an existing primary conductor without disconnecting the cable or interrupting the load. It is the standard choice for retrofit energy monitoring, sub-metering, and load studies where shutdown is not acceptable.

It is not a solid-core CT replacement for every case. The split-core air gap introduces a small magnetic penalty compared with a closed-core design at the same nominal rating. Fullstar's SCT series is engineered to keep that penalty within IEC 61869 Class 0.5 / Class 1.0 limits across the rated range, verified on our in-house calibration bench for every production batch. If your application requires 0.2S revenue-grade accuracy at very low current, a solid-core or Rogowski solution may be more appropriate

split core current transformer6.jpg

split core current transformer7.jpg

Technical Specifications

Parameter Specification
Product type Split-core AC current transformer / sensor
Standards Designed and tested to IEC 61869-2 accuracy class 0.5 / 1.0; insulation and safety per applicable IEC/UL requirements (declaration available)
Primary current range 0.01 A – 10,000 A (model-dependent)
Secondary output options 33.3 mA, 100 mA, 1 A, 5 A; voltage output (e.g., 0.333 V) available on request
Accuracy class 0.5 / 1.0 (IEC 61869-2) - model-specific
Window / hole diameter 10 mm / 16 mm / 24 mm / 36 mm (custom sizes available)
Frequency 50–60 Hz standard; 50 Hz–1 kHz on select models
Insulation / encapsulation Epoxy resin encapsulated; ABS / PBT flame-retardant housing (UL94-V0 where applicable)
Mounting / closing Locking snap or hinged closure; primary conductor must be centered in window
Customization Turns ratio, output type, lead length, connector, and housing marking customizable for OEM volumes

photobank (1)

 

Application Solutions - matched to the way you actually buy

Retrofit energy monitoring without cable disconnection

Problem: Building or data-center feeders cannot be shut down for CT installation.
Solution: SCT split-core series with locking snap closure - installs around existing cable in minutes, no torque tool required.
Recommended models: SCT016T / SCT024TS for 120–400 A feeders; SCT036TS for 600 A feeders.
 

 

photobank (3)

Downloads - engineering resources for your evaluation

Resource Format What it covers
SCT Series Datasheet PDF Full model list, IEC accuracy tables, ratio/phase error curves, dimensional drawings
Installation & Safety Guide PDF Closure inspection, air-gap cleanliness, conductor centering, lead routing, torque-free locking check
2D Drawing / 3D STEP DWG / STEP Main models for panel layout and CAD integration
Declaration of Conformity (template) PDF IEC 61869-2 / RoHS / REACH statements
ISO 9001 Certificate PDF Scope, issuing body, validity
Retrofit Application Note PDF Step-by-step retrofit workflow with photos and common installation errors

 

Selection & Installation Notes - from our engineering team

Engineer's Note 1 - Air gap is the accuracy killer in split-core CTs.
The mating surfaces of the core halves must be clean and fully closed before the lock engages. A single layer of paint, dust, or oxidation at the gap can shift phase error enough to fail a Class 0.5 check at low current. We recommend wiping the mating faces with a dry lint-free cloth immediately before closing, and never forcing the lock if resistance is felt.

Engineer's Note 2 - Centering matters more than most datasheets admit.
An off-center primary conductor in the window introduces an additional error component. For Class 0.5 work. If the cable bundle is irregular, use a cable tie to bundle and center it before closing the CT.

Engineer's Note 3 - Do not rely on nominal current alone for model selection.
A 400 A CT used on a feeder that idles at 20 A may still have acceptable ratio error, but phase error at that low current can dominate the meter's accuracy budget. If your load profile includes long low-current periods, ask for phase-error data at 1–5% rated current, not just at nominal. We provide this data on request for all Class 0.5 models.

 

Company Information

We a premier professional manufacturer specializing in magnetic components and electronic solutions. Founded in 2009 and headquartered in the high-tech hub of Xi'an, we have accumulated over 15 years of deep expertise in the research, development, and production of high-performance transformers and inductors. Our facility spans 3,000 square meters and is powered by a dedicated workforce of 300+ skilled professionals, including a senior R&D team focused on bespoke magnetic designs.

Our comprehensive product line features high-frequency and low-frequency transformers, toroidal transformers, current transformers, and a wide variety of inductors and magnetic cores. As a Top 6 leading factory for Industrial Controls, we provide critical components for power supplies, telecommunications, automotive electronics, and green energy sectors globally.

Quality is our core competency. Fullstar operates under a strict ISO9001:2015 Quality Management System. Our products carry international safety and environmental certifications including UL, CE, RoHS, and REACH. Every unit undergoes a 100% rigorous testing process before shipment to ensure zero-defect reliability in demanding industrial environments.

We excel in customization. With advanced design-based and sample-based capabilities, we offer rapid 7-day prototyping and flexible OEM/ODM services. Our supply chain reaches over 80 countries, providing localized support and cost-effective logistics. Whether you require high-volume production or small-batch custom coils, Fullstar delivers precision-engineered magnetic components that drive your innovation forward. We welcome global business inquiries for long-term strategic partnerships.

QQ20260409154814

Why Choose Fullstar?

QQ20261125172202

With Chips As Wings, We Shine On The World Stage

With over 20 years of industry experience, Fullstar delivers customized, high-quality components and power solutions to customers across diverse industries-from consumer electronics and industrial automation to automotive, telecommunications, medical devices, and renewable energy. We are an ISO 9001:2015 certified company, committed to rigorous quality management at every stage-from design and prototyping to mass production and delivery.Our brand values-Three F': Focused, Flawless, Forward-thinking.Our product value-Three Highs: High Performance, High Stability, High Precision.Our mission: Deliver reliable "core" components for global electronics.

 

 

Certification And Exhibition

 

QQ20260409154833

QQ20260409154908

FAQ

Q: What is the difference between your split-core sensor and a solid-core CT?
A: Split-core installs without disconnecting the conductor; solid-core typically requires shutdown or cable re-routing. Split-core has a small magnetic penalty from the air gap. For retrofit and temporary monitoring, split-core is usually the pragmatic choice; for permanent revenue metering at very low current, evaluate solid-core or Rogowski alternatives with our engineer.

 

Q: Can you provide a sample for evaluation before mass order?
A: Yes. Samples can be supplied with a calibration record for the requested accuracy class. MOQ for custom ratios/leads applies after sample approval.

 

Q: Which documents can you provide for our quality/compliance review?
A: ISO 9001 certificate, IEC 61869-2 test report (model-specific, under NDA where required), RoHS/REACH DoC, and dimensional/CAD files.

 

Q: What is the warranty and failure-handling policy?
A: For batch-level issues, we provide replacement or credit after root-cause analysis; field failure samples should be returned for teardown.

 

Q: Can you customize the turns ratio, lead length, and connector?
A: Yes, for OEM volumes. Customization requires a drawing approval.Send your specification for feasibility review.